*The high-precision evaporator has the stable output concentration with pressure, temperature, and flow automatic compensation; Choose one among Enflurane, Isoflurane and Sevoflurane.
*Reliable gas Power transmission system;
* Reasonable economic and multiple technology configuration, the user s may choose flexibly;
*Modular product design can be upgrade according to users’ need
Main Technical Parameters
Part of Anesthesia Machine
*Console high-strength engineering plastic rack, light, beautiful and corrosion resistance
*Scope adult, child
*Gas source O2:0.3~0.5MPa
*Flow meter O2:0.1~2L/min 2.5~10L/min
*Rapid oxygen flow 35~75L/min
*Low oxygen pressure alarm it will be alarmed when the oxygen pressure < 0.2MPa
*Vaporizer
It has the function of pressure, temperature, and flow automatic compensation. the regulation range of evaporator concentration is 0~5vol%. Choose one among Enflurane, Isoflurane and Sevoflurane for a matching according to the demands of customer.
*Respiratory circuit work mode all close. semi-close. semi-open pressure release 1~4KPa
*Bellows breathing adults and children bellows tidal volume range:0~1500ml
Part of Ventilator
*Display mode high brightness LED display
*Ventilation mode IPPV
*Ventilation parameters
Tidal volume 50~1500ml
Frequency 6~60 bpm
Breath /expiratory ratio 2:1~1:3
Airway pressure range -2~10 Kpa
*Ventilation monitoring parameters
Tidal volume. ventilation. respiratory rate. airway pressure
Breath /expiratory ratio.
*Security Alert System
Alarm minute ventilation
Fixed ceiling value 18L/min
Fixed threshold value 1~10L/min
Asphyxia alarm
The machine will give sound and light alarm if there is no tidal volume input in 15s
Power failure alarm
*Reliable gas Power transmission system;
* Reasonable economic and multiple technology configuration, the user s may choose flexibly;
*Modular product design can be upgrade according to users’ need
Main Technical Parameters
Part of Anesthesia Machine
*Console high-strength engineering plastic rack, light, beautiful and corrosion resistance
*Scope adult, child
*Gas source O2:0.3~0.5MPa
*Flow meter O2:0.1~2L/min 2.5~10L/min
*Rapid oxygen flow 35~75L/min
*Low oxygen pressure alarm it will be alarmed when the oxygen pressure < 0.2MPa
*Vaporizer
It has the function of pressure, temperature, and flow automatic compensation. the regulation range of evaporator concentration is 0~5vol%. Choose one among Enflurane, Isoflurane and Sevoflurane for a matching according to the demands of customer.
*Respiratory circuit work mode all close. semi-close. semi-open pressure release 1~4KPa
*Bellows breathing adults and children bellows tidal volume range:0~1500ml
Part of Ventilator
*Display mode high brightness LED display
*Ventilation mode IPPV
*Ventilation parameters
Tidal volume 50~1500ml
Frequency 6~60 bpm
Breath /expiratory ratio 2:1~1:3
Airway pressure range -2~10 Kpa
*Ventilation monitoring parameters
Tidal volume. ventilation. respiratory rate. airway pressure
Breath /expiratory ratio.
*Security Alert System
Alarm minute ventilation
Fixed ceiling value 18L/min
Fixed threshold value 1~10L/min
Asphyxia alarm
The machine will give sound and light alarm if there is no tidal volume input in 15s
Power failure alarm