Mass Flow Meter
1. Apply high stability and patented technology platinum RTD sensor
2.Uses proprietary technology "balanced structure package", medium temperature self-compensation.
3. Proprietary algorithms; can achieve high linearity, high repeatability, high precision.
4. Range ratio 1000:1, also can be expanded according to user requirements.
5. Enables measurement of small flow large diameter, minimum flow rate can be measured as low as zero, resolution0.001m/s.
6. No moving parts, vibration can be neglected.
7. Straight pipe less demanding 1-2D.
8. Unrelated with the medium temperature and pressure.
9. Proprietary high-temperature method, medium temperature up to +510 .
10. Humidity algorithm used to achieve high precision measurement.
11. Flow signal enter 12-point dynamic correction, built-in 10-point amendment.
12. Dynamic on-line correction current / voltage output.
13. Dont sensitive to dust and other small particles.
14. On-line continuous flow, easy handling and maintenance.
Performance:
* Measuring range: 0~120Nm/s (20C,101.33Kpa)
* Accuracy: ± 1% of reading ± 0.5% full scale
* Range ratio: usually 100:1 (depending on the calibration of flow range)
* Diameter range: 10mm ~ 6000mm
* Application scope: suitable for all types of single or mixed gases, containing dust, sand, moisture and various corrosive gases.
* Environmental temperature range: -40 ~ +85 (no display); -30 ~ +70 (showing); humidity is less than 90% RH.
* Medium temperature range: -40 ~ +100 ; -40 ~ +200 ; -40 ~ +450 ; -40 ~ +510
* Sensor Diameter: 3, 2.5
* Plug-in sensor probe rod diameter: 19 (standard), 16, 12
* Sensor Material: 316 stainless steel, Hastelloy, Titanium
* Probe rod material (protection cover): 316 stainless steel (standard), Hastelloy
* Medium bi-directional flow measurement
* Analog Output: Flow :4-20mADC, temperature :4-20mADC, maximum load: 1000Ω
2.Uses proprietary technology "balanced structure package", medium temperature self-compensation.
3. Proprietary algorithms; can achieve high linearity, high repeatability, high precision.
4. Range ratio 1000:1, also can be expanded according to user requirements.
5. Enables measurement of small flow large diameter, minimum flow rate can be measured as low as zero, resolution0.001m/s.
6. No moving parts, vibration can be neglected.
7. Straight pipe less demanding 1-2D.
8. Unrelated with the medium temperature and pressure.
9. Proprietary high-temperature method, medium temperature up to +510 .
10. Humidity algorithm used to achieve high precision measurement.
11. Flow signal enter 12-point dynamic correction, built-in 10-point amendment.
12. Dynamic on-line correction current / voltage output.
13. Dont sensitive to dust and other small particles.
14. On-line continuous flow, easy handling and maintenance.
Performance:
* Measuring range: 0~120Nm/s (20C,101.33Kpa)
* Accuracy: ± 1% of reading ± 0.5% full scale
* Range ratio: usually 100:1 (depending on the calibration of flow range)
* Diameter range: 10mm ~ 6000mm
* Application scope: suitable for all types of single or mixed gases, containing dust, sand, moisture and various corrosive gases.
* Environmental temperature range: -40 ~ +85 (no display); -30 ~ +70 (showing); humidity is less than 90% RH.
* Medium temperature range: -40 ~ +100 ; -40 ~ +200 ; -40 ~ +450 ; -40 ~ +510
* Sensor Diameter: 3, 2.5
* Plug-in sensor probe rod diameter: 19 (standard), 16, 12
* Sensor Material: 316 stainless steel, Hastelloy, Titanium
* Probe rod material (protection cover): 316 stainless steel (standard), Hastelloy
* Medium bi-directional flow measurement
* Analog Output: Flow :4-20mADC, temperature :4-20mADC, maximum load: 1000Ω
Certificate
- ISO9001: 2000
- ISO14001: 2004
- OHSAS18001: 2007
Main Products
Differential Pressure Switch, Flow Switch, Flow Sensor