JX-8000 patient monitor
Standard configuration: ECG, HR, PR, SpO2, OxyCRG diagram, ST analysis, Arrhythmia analysis, RESP*2 (RA-LL impedance and nasal cavity), NIBP (with venous punch), TEMP*2(surface and rectal type), Drug dose calculation and lead-acid battery.
Optional configuration:
Wireless networking function to patient monitor;
Inside placed thermal-sensitive built-in printer;
IBP function (Include 1 pressure sensor and 1 adaptable cable);
ETCO2 function module(Include 1 disposable dehydration bottle);
Wall Mount for patient monitor ;
Trolly for patient monitor;
12 volts Power supply for ambulance
Physical Character
1. Displayer :12.1" color TFT LCD screen with maximum 8-waveform display.
2. Battery: Rechargeable high-energy built-in battery
3. Advanced streamline outline design, portable, compact, lightweight
4. Operating menu with multi-language interface selection: English, Spanish, Portuguese, Chinese, Arabic, Russian, Italian, etc.
5. Easy operation with user friendly menu structure design and rotary dial
6. Against & eliminate ESU interference & defibrillation, no need to disconnect the monitor from the patient in process of defibrillating.
7. Three-application mode: monitoring, diagnosis, operating.
8. WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible
9. Optional built-in wireless networking function
10. 72 hours data storage.
11. Intelligent audio and visual comprehensive alarm
12. In-hospital applications include emergency room’s pre and post operative care, ICU, Operation room/theater, ambulatory surgery, intermediate care/step down units, labor and delivery, and hospital-based special procedure areas.
13. Suitable for use in physicians’ offices, clinics, outpatient surgical centers, extended care facilities and other patient care areas, which of require affordable monitoring
14. Suitable for adult, pediatrics, neonates
Technical Parameter
Temperature (surface and rectal)
Measurement range: 25.0degrees to 45.0 degrees
Accuracy: ± 0.1 degrees
Resolution: 0.1 degrees
response time: ≤ 3 min.
ECG
Input: 5 wires ECG cable
Lead section:Ⅰ,Ⅱ,Ⅲ/ aVR, aVL, aVF/ V
Gain(mm/mV): 1/4,1/2,1,2,4
Frequency response: Diagnosis 0.05 - 100Hz
Monitor 0.5 - 40 Hz
Surgery 1.0 - 25 Hz
Sweep speed(mm/sec): 12.5, 25, 50
Heart rate range: 30-254 BPM
Heart rate accuracy: ± 1 %
ST segment deviation analysis: -0.8-+0.8mV
ST accuracy: ±0.02mv
Respiration Rate(RA-LL impedance and nasal cavity)
Measurement range: 0 - 120 BPM(adult)
Accuracy: ± 1 BPM or 5 %
Resolution: 1 BPM
Power requirements
Input: 98~260 V AC, 50/60Hz
Consumption: ≤ 80VA
Environment
Operation Storage
Temperature 0.5 to 40 degrees -20 to 50 degrees
Relative humidity ≤ 80%
Pulse Rate
SPO2 measurement range: 0 - 100 %
Resolution: 1 %
Pulse measurement range: 30- 254BPM
Accuracy: ± 2 %
Resolution: 1 BPM
NIBP (Non-invasive blood pressure)
Measurement type : adult, pediatric, neonatal
Measurement range: Systolic 4.0 - 37.0 kPa
Diastolic 1.3 - 33.0 kPa
Mean 2.6 - 35.0 kPa
Accuracy : ± 0.4 kPa or 5 %
Resolution: 0.1 kPa
Protection: over pressure
IBP(Invasive blood pressure) (with venous punch)
(Option)
Measurement range: -1.3~40kPa (-10~300mmHg)
Channel: 2 channel
Transducer sensitivity: 5MV/V/mmHg
Unit display: KPa or mmHg selectable
ETCO2 (side stream type) (Option)
Measurement range: 0 % - 10.0 % (ins CO2 and et CO2)
Accuracy: ± 2 mm Hg (< 5 % Measurement value)
10 % (> 5 % Measurement value)
Response time: 180 Ms ≤ 90%
Accessories for Standard configuration:
1 set of ECG cable
10 pcs of ECG electrode
1 set of NIBP extend cable
1 set of NIBP adult or pediatric or neonate cuff
1 set of RESP nasal cavity pipe
1 set of TEMP surface probe
1 set of TEMP cavity probe
1 set of integrated adult or pediatric or neonate SpO2 sensor
1 set of power supply cable
Standard configuration: ECG, HR, PR, SpO2, OxyCRG diagram, ST analysis, Arrhythmia analysis, RESP*2 (RA-LL impedance and nasal cavity), NIBP (with venous punch), TEMP*2(surface and rectal type), Drug dose calculation and lead-acid battery.
Optional configuration:
Wireless networking function to patient monitor;
Inside placed thermal-sensitive built-in printer;
IBP function (Include 1 pressure sensor and 1 adaptable cable);
ETCO2 function module(Include 1 disposable dehydration bottle);
Wall Mount for patient monitor ;
Trolly for patient monitor;
12 volts Power supply for ambulance
Physical Character
1. Displayer :12.1" color TFT LCD screen with maximum 8-waveform display.
2. Battery: Rechargeable high-energy built-in battery
3. Advanced streamline outline design, portable, compact, lightweight
4. Operating menu with multi-language interface selection: English, Spanish, Portuguese, Chinese, Arabic, Russian, Italian, etc.
5. Easy operation with user friendly menu structure design and rotary dial
6. Against & eliminate ESU interference & defibrillation, no need to disconnect the monitor from the patient in process of defibrillating.
7. Three-application mode: monitoring, diagnosis, operating.
8. WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible
9. Optional built-in wireless networking function
10. 72 hours data storage.
11. Intelligent audio and visual comprehensive alarm
12. In-hospital applications include emergency room’s pre and post operative care, ICU, Operation room/theater, ambulatory surgery, intermediate care/step down units, labor and delivery, and hospital-based special procedure areas.
13. Suitable for use in physicians’ offices, clinics, outpatient surgical centers, extended care facilities and other patient care areas, which of require affordable monitoring
14. Suitable for adult, pediatrics, neonates
Technical Parameter
Temperature (surface and rectal)
Measurement range: 25.0degrees to 45.0 degrees
Accuracy: ± 0.1 degrees
Resolution: 0.1 degrees
response time: ≤ 3 min.
ECG
Input: 5 wires ECG cable
Lead section:Ⅰ,Ⅱ,Ⅲ/ aVR, aVL, aVF/ V
Gain(mm/mV): 1/4,1/2,1,2,4
Frequency response: Diagnosis 0.05 - 100Hz
Monitor 0.5 - 40 Hz
Surgery 1.0 - 25 Hz
Sweep speed(mm/sec): 12.5, 25, 50
Heart rate range: 30-254 BPM
Heart rate accuracy: ± 1 %
ST segment deviation analysis: -0.8-+0.8mV
ST accuracy: ±0.02mv
Respiration Rate(RA-LL impedance and nasal cavity)
Measurement range: 0 - 120 BPM(adult)
Accuracy: ± 1 BPM or 5 %
Resolution: 1 BPM
Power requirements
Input: 98~260 V AC, 50/60Hz
Consumption: ≤ 80VA
Environment
Operation Storage
Temperature 0.5 to 40 degrees -20 to 50 degrees
Relative humidity ≤ 80%
Pulse Rate
SPO2 measurement range: 0 - 100 %
Resolution: 1 %
Pulse measurement range: 30- 254BPM
Accuracy: ± 2 %
Resolution: 1 BPM
NIBP (Non-invasive blood pressure)
Measurement type : adult, pediatric, neonatal
Measurement range: Systolic 4.0 - 37.0 kPa
Diastolic 1.3 - 33.0 kPa
Mean 2.6 - 35.0 kPa
Accuracy : ± 0.4 kPa or 5 %
Resolution: 0.1 kPa
Protection: over pressure
IBP(Invasive blood pressure) (with venous punch)
(Option)
Measurement range: -1.3~40kPa (-10~300mmHg)
Channel: 2 channel
Transducer sensitivity: 5MV/V/mmHg
Unit display: KPa or mmHg selectable
ETCO2 (side stream type) (Option)
Measurement range: 0 % - 10.0 % (ins CO2 and et CO2)
Accuracy: ± 2 mm Hg (< 5 % Measurement value)
10 % (> 5 % Measurement value)
Response time: 180 Ms ≤ 90%
Accessories for Standard configuration:
1 set of ECG cable
10 pcs of ECG electrode
1 set of NIBP extend cable
1 set of NIBP adult or pediatric or neonate cuff
1 set of RESP nasal cavity pipe
1 set of TEMP surface probe
1 set of TEMP cavity probe
1 set of integrated adult or pediatric or neonate SpO2 sensor
1 set of power supply cable
Certificate
- ISO9001
Main Products
ventilator, anesthesia machine, patient monitor