Model 1000VA 1500VA 2000VA 3000VA
Real Power Rating 600W 900W 1200W 1800W
Display
Indicator on Panel LED / LCD plus LED display
AC Mode
Types Of Load Ancillary equipments such as PC, display, group computers and so on
Input Voltage 165Vac ~ 275Vac / 150Vac-275Vac(optional)
Input Frequency 45-65 Hz( transfer to battery mode if out of this range)
Output voltage 220Vac± 10%
Efficiency ≥ 96% (AC Mode)
Overload in AC mode 110% transfer to bypass within 60sec;
120% transfer to bypass within 30sec;
Automatically recovery if decrease the load capacity.
Short Circuit Protected by Input Fuse
Inverter Mode
Output Voltage 220Vac± 5%
Output Frequency 50HZ/60HZ ± 1% self-detection
Output P.F ≥0.6
Waveform Distortion Liner Load ≤ 5%
Battery Backup Time ≥ 10min (PC load)
Transfer Time Typical value 5ms, Max: 8ms
Efficiency ≥ 80(INV Mode)
Overload in INV mode 110% Shut down within 60sec;
120% Shut down within 5sec;
Short Circuit ≥20ms System shut down automatically
Alarm
AC abnormal Once every 4sec, be silent after 40s
Battery low Once every 0.2sec
Overload Once every 1sec
Battery
DC voltage 24V 24V 36V 48V
Configuration 2×12V7AH 2×12V8AH 3×12V 8AH 4×12V 8AH
Recharge Time 90% Capacity after 8hours
Communication RS232/USB/SNMP(can be set to turn on/off UPS automatically)
Others
Output Sockets Customized upon request
IP Level IP20
Ambient Temperature 0℃ ~ 40℃
Ambient Humidity 10% ~ 90% (No Condensing)
Noise ≤50dB (1m)
Dimension(mm)
D*W*H 360×145×215 430×145×215 475×200×337
Packing Dimension(mm) 450×325×245 510×325×245 590×320×465
Net Weight (kg) 14.5 15.5 18.5 27
Gross Weight (kg) 15.5 16.5 19.5 28.60
Real Power Rating 600W 900W 1200W 1800W
Display
Indicator on Panel LED / LCD plus LED display
AC Mode
Types Of Load Ancillary equipments such as PC, display, group computers and so on
Input Voltage 165Vac ~ 275Vac / 150Vac-275Vac(optional)
Input Frequency 45-65 Hz( transfer to battery mode if out of this range)
Output voltage 220Vac± 10%
Efficiency ≥ 96% (AC Mode)
Overload in AC mode 110% transfer to bypass within 60sec;
120% transfer to bypass within 30sec;
Automatically recovery if decrease the load capacity.
Short Circuit Protected by Input Fuse
Inverter Mode
Output Voltage 220Vac± 5%
Output Frequency 50HZ/60HZ ± 1% self-detection
Output P.F ≥0.6
Waveform Distortion Liner Load ≤ 5%
Battery Backup Time ≥ 10min (PC load)
Transfer Time Typical value 5ms, Max: 8ms
Efficiency ≥ 80(INV Mode)
Overload in INV mode 110% Shut down within 60sec;
120% Shut down within 5sec;
Short Circuit ≥20ms System shut down automatically
Alarm
AC abnormal Once every 4sec, be silent after 40s
Battery low Once every 0.2sec
Overload Once every 1sec
Battery
DC voltage 24V 24V 36V 48V
Configuration 2×12V7AH 2×12V8AH 3×12V 8AH 4×12V 8AH
Recharge Time 90% Capacity after 8hours
Communication RS232/USB/SNMP(can be set to turn on/off UPS automatically)
Others
Output Sockets Customized upon request
IP Level IP20
Ambient Temperature 0℃ ~ 40℃
Ambient Humidity 10% ~ 90% (No Condensing)
Noise ≤50dB (1m)
Dimension(mm)
D*W*H 360×145×215 430×145×215 475×200×337
Packing Dimension(mm) 450×325×245 510×325×245 590×320×465
Net Weight (kg) 14.5 15.5 18.5 27
Gross Weight (kg) 15.5 16.5 19.5 28.60
Certificate
- CQC
- CE
- UL
- ROHS
Main Products