Multiparameter Monitor--MD908
Meditech MD908 is a compact Multi-parameter monitor with color TFT display. It has standard parameters as ECG, NIBP and SPO2, and optional parameters as RESP, 2-TEMP, 2-IBP, ETCO2, Network, Thermal Printer, Pacing Maker.
Specifications
- ECG
- Lead Mode 5 Leads ( R, L, F, N, C or RA, LA, LL, RL, V)
- Lead selection I, II, III, avR, avL, avF, V,
- Waveform 2 ch
- Lead mode 3 Leads ( R, L, F or RA, LA, LL)
- Lead selection I, II, III,
- Waveform 1 ch
- Gain ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV
- NIBP
- Method Oscillometric
- Mode Manual, Auto, STAT
- Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 Min
- Measuring Period in STAT Mode 5 Min
- Pulse Rate Range 40 ~ 240 bpm
- Alarm Type SYS, DIA, MEAN
- Measuring and alarm Range Adult Mode
- SYS 40 ~ 270 mmHg
- DIA 10 ~ 215 mmHg
- MEAN 20 ~ 235 mmHg
- Pediatric Mode
- SYS 40 ~ 200 mmHg
- DIA 10 ~ 150 mmHg
- MEAN 20 ~ 165 mmHg
- Neonatal Mode
- SYS 40 ~ 135 mmHg
- DIA 10 ~ 100 mmHg
- MEAN 20 ~ 110 mmHg
- Resolution
- Pressure 1mmHg
- Accuracy Pressure
- Maximum Mean error ±5mmHg
- Maximum Standard deviation ±8mmHg
- Overpressure Protection
- Adult Mode 297±3 mmHg
- Pediatric Mode 240±3 mmHg
- Neonatal Mode 147±3 mmHg
- SpO2
- Measuring Range 0 ~ 100 %
- Alarm Range 0 ~ 100 %
- Resolution 1 %
- Accuracy 70% ~ 100% ±2 %
- 0% ~ 69% unspecified
- Actualization interval about 1Sec.
- Alarm Delay 10 Sec.
- Pulse Rate
- Measuring and Alarm Range
- 0~254bpm
- Resolution 1bpm
- Accuracy ±2bpm
- Alarm Delay 10 Sec.
- MASIMO Specification:
- Range
- Saturation(%SpO2) 1%~100%
- Pulse Rate(bmp) 25~240
- Accuracy
- Saturation(%SpO2) - During No Motion Conditions*
- Adults 70%-100%±2digits
- 0%-69% unspecified
- Neonates 70%-100%±2digits
- Saturation(%SpO2) - During Motion Conditions**
- Adults 70%-100%±3digits
- 0%-69% unspecified
- Neonates 70%-100%±3digits
- Pulse(bpm) - During No Motion Condition 25 to 240 ± 3digits
- Pulse(bpm) - During Motion Condition 25 to 240 ± 5digits
- Resolution
- Saturation(%SpO2) 1%
Features
- ECG
- Lead type : 5-lead
- Input : RA; LA ;RL ;LL ;V
- Sweep speed : 12.5mm/s, 25mm/s, 50mm/s
- Accuracy : 1¾1bpm or 1¾1%, which is greater
- Protection : Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
- S-T detection : YES, Arrhythmia analysis : YES
- Alarm : YES, audible and visual alarm, alarm events recallable NIBP
- Method : Oscillometry
- Operation modes : Manual/Automatic/STAT
- Measurement unit : mmHg / KPa selectable
- Measurement types : Systolic, Diastolic, Mean
- Over-pressure protection : YES
- SPO2
- Measurement range : 0-100%
- Accuracy : 2digit(70~100%)
- 0~69% unspecified
- Standard Configuration
- ECG, NIBP, SPO2
Main Products