VX7000R 12 channels universal input, color screen paperless recorder can input signals such as standard electric current, standard voltage, frequency, millivolt, thermocouple,thermal resistance and so on. It has the function of sensor isolated electronic division outputting, relay alarm outputting, transition outputting, flow rate accumulation , temperature and pressure compensation, historical data unloading, printing and remote communication.
Specifications
- Color display
- 320*240 pixel, LCD
- Analog inputs
- The paperless recorder can be internally equipped with 1 to 12 analog inputs. Can receive 4-20mv,1-5v, thermocouple (S,B,K,T,E,J,R,N,WRE,F1,F2) resistance thermometer( Pt100, Cu50, Cu53, BA1,BA2), 0-20mV, 0-100mV, 0-10mA, 0-5v,0-350Ωand other analog signals
- Recording capacity
- Approx 26,000 measurements per channel . Different storage rates , ranging from 1 sec to 4 min, determinates the recording duration capacity, ranging from 72 hours to 720 days
- Precision
- 0.2% full scale
- Electrical relay output
- The paperless recorder can be internally equipped with 1 to 8 electrical relay output. 220VAC 3A
Features
- Input signals
- Can input various standard signals such as Fr, 20mA, 5V, S , B, K, T, E, J, R, N, P1100, Cu50, CU53, BA1, BA2, 350Ω, 20mV, 100mV,10mA,WRe,F1 and F2.
- Accuracy
- The Accuracy of the signal full range is ?.2%.
- Supply
- supply isolated electronic distribution.
- supply standard 4~20mA output.
- Communication
- ◆Standard serial communication interface:RS-485 and RS-232C.
- ◆10M Ethernet standard RJ45 interface.
- ◆Support standard ModbusRTU communication protocol and standard ModbusTCP communication protocol.
- ◆Use USB interface to upload and backup historical data. It supports USB disk of 256M~2G.
- ◆Support FAT16/FAT32 file system,.
- ◆Supports manual printing and timed automatic printing.
- Software
- ◆Display 5 digits engineer value:-9999~19999.
- ◆Display alarm and instructs every channel's LL alarm,L alarm, H alarm and HH alarm. And can record the last 15 items of alarm information.
- ◆flow rate accumulation .
- ◆Max 4 groups of temperature and pressure compensation. It support many types of compensation models. For example, common compensation models such as superheated steam, saturated steam and pressure compensation.
- ◆Support Vacuum Scientific number scale displaying
- ◆The form feeding way of the trend can be set horizontal or vertical.
- ◆Every four groups of trends can combine freely to display, and can define the color freely.
Main Products