NCA1C hall transducer
NCA1C 50, 100, 200, 300, 400, 500, 600A hall transducer
Specifications
- Main technical data:
- 1. Primary normal current IPN (r.m.s) Primary current measuring range IP Type
- 50A +/-150A NCA1C-50A
- 100A +/-300A NCA1C-100A
- 200A +/-600A NCA1C-200A
- 300A +/-900A NCA1C-300A
- 400A +/-900A NCA1C-400A
- 500A +/-900A NCA1C-500A
- 600A +/-900A NCA1C-600A
- 2. Supply voltage(+/-5%): +/-15V
- 3. Current consumption: ≤25mA
- 4. Isolation test: Between the primary circuit
- to the secondary circuit(+.-.M): 3kVrms/50Hz/1min
- 5. Normal output voltage @RL=10Kω,TA=+25 oC: 4V
- 6. Loading resistance: ≥10kΩ
- Accuracy – Dynamic performance Data
- 1. Accuracy @ IPN, TA=+25 oC: +/-1%
- 2. Non-linearity (0~ IPN): +/-1%
- 3. Electrical offset voltage VOE, TA=+25oC : ≤+/-40mV
- 4. Thermal drift of VOE: ≤±1mV/℃(-10 oC ~+70 oC)
- 5. Response time (@ 90% of IP): ≤3us
- 6. di/dt accurately followed: > 50A/us
- 7. Frequency bandwidth(0.5dB): DC 0~50kHz
- General data:
- 1. Operating temperature: -10 oC ~+70 oC
- 2. Storage temperature: -25 oC ~+85 oC
- 3. Weight: approx. 60g±5g
- 4. Standards: EN50178
- Features:
- 1. Hall effect measuring principle
- 2. Galvanic isolation between primary and secondary circuit
- 3. Insulated plastic case made of white PPO recognized according to UL 94-V0
- 4. The whole current transducer comply with RoHS Directive completely
Features
- Product Characteristics
- High accuracy
- Low thermal drift
- Good anti-interference performance
- Good current overload capability
- Small size and easier installation
- conform to UL94-V0 standard
Certificate
- 9001&2000
- ROHS
- CE
Main Products
current/voltage transducer,current/voltage sensor,pressure sensor