Measure SO2,NO,CO,CO2,O2,T,P,Flow simultaneously.
Specifications
- Gas Parameter
- Measurement Principle:
- Micro-Flow NDIR : SO2,NO,CO,CO2
- Electrochemistry: O2
- Measurement Range :
- SO2:0-2000PPM
- NO: 0-2000PPM
- CO: 0-5000PPM
- CO2:0-25%
- O2: 0-25%
- Resolution:
- SO2/NO/CO: 1PPM
- CO2/O2: 0.01%
- Precision:
- SO2,NO,CO,CO2 : 1%FS
- O2: 2%FS
- Temperature Parameter
- Measurement Principle:
- Ambient Temperature:Thermistor
- Flue Gas Temperature: Thermocouple
- Range:
- Ambient Temperature :-10-100℃
- Flue Gas Temperature : -10-600℃
- Resolution:
- Ambient Temperature 1℃
- Flue Gas Temperature 1℃
- Precision:
- Ambient Temperature ?℃
- Flue Gas Temperature ?℃
- Pressure Parameter:
- Measurement Principle:
- Diff. Pressure: Silicon Diff. Pressure Chip
- Ambient Pressure: Silicon Pressure Chip
- Range:
- Diff. Pressure:-50hPA ...+50hPA
- Ambient Pressure: 70KPA...120KPA
- Resolution:
- Diff. Pressure: 1PA
- Ambient Pressure: 0.01KPAR
- Precision:
- Diff. Pressure: ?PA or 5%REL
- Ambient Pressure: ?.5 Kpa or 2 % rel.
Features
- Portable flue gas analyzer
- Function :
- Based on Micro-Flow NDIR technology.
- Measure SO2,NO,CO,CO2,O2,T,P,Flow simultaneously.
- No effect of H2O on the measure result of SO2 and NO.
- No constant flow requirement for SO2/NO/CO/CO2.
- Built-in pump
- Calculation of Lambda and combustion efficiency automatically.
- LCD 320 x 240 display,RS232 digital output
Main Products
Flue gas analyzer,biogas analyzer,coal gas analyzer