Specifications
- Standard rating: 3~40 Ampere
- Input power: 50VDC/125VAC/250VAC
- Dielectric strength: 1500VAC/1 minute
- Interrupt capacity: 1000A
- Insulation resistance: > 100Mohms
- Operating temp: -20 ~ +90 Celsius
- Voltage drop: 0.9V or less
- Endurance: over 500 on/off cycles
- Overload: 600%, trip time (3-4A): 0.6-2.0sec
- Overload: 500%, trip time (3-4A): 1.0-5.0sec
- Overload: 400%, trip time (3-4A): 1.2-8.0sec
- Overload: 300%, trip time (3-4A): 2.5-11.0sec
- Overload: 200%, trip time (3-4A): 4.0-40.0sec
- Overload: 165%, trip time (3-4A): trip within 1hr
- Overload: 100%, trip time (3-4A): no trip
- Overload: 600%, trip time (5-40A): 0.6-1.7sec
- Overload: 500%, trip time (5-40A): 0.8-2.5sec
- Overload: 400%, trip time (5-40A): 1.6-7.0sec
- Overload: 300%, trip time (5-40A): 2.5-11.0sec
- Overload: 200%, trip time (5-40A): 4.0-30.0sec
- Overload: 150%, trip time (5-40A): trip within 1hr
- Overload: 100%, trip time (5-40A): no trip
- Overload: 200%, trip time (35-40A): trip within 1min
Features
- Reset: manual or auto
- Safety: CSA, UL, SAA, VDE, CE, ISO 9002
- Application: AC & DC motor, generator, power strip, common protection
- Over 9 different type
Main Products
overload & overheat control unit, switches, audio plug & jack, circuit breaker