Specifications
- Electrical:
- Input voltage: 110, 115 or 220, 240VAC nominal user selectable
- On line voltage range: low 85, 93 or 165, 185V / high135, 140 or 256, 285V user selectable
- Input frequency: 47 ~ 53HZ or 57 ~ 63HZ
- Surge protection: IEEE 587/ANSI C62.41(level A & B) or IEC801-5
- Surge energy rating: 240Joules
- Peak current capability: 6500A
- Normal mode clamping time: 0ns, < 5ns typical
- Normal mode noise: full time EMI / RFI filtering
- Suppression on-battery voltage: +/-5%
- Regulation waveform: stepped approximation to sine wave output
- Power factor: 0.6(1000A/1200A), 0.7(1200TA/1500TA/2000TAL)
- AC overload protection: fuse(1000A/1200A), on battery-internal current limit, on line-circuit breaker(1200TA/1500TA/2000TAL)
- On-line efficiency: 96%
- Options: N/A(1000A/1200A), charging PC board(1200TA/1500TA/2000TAL)
- Battery:
- Battery type: sealed maintenance free lead-acid
- Full/half load support time: 5 ~ 30 Min depending on computer load.
- Recharge time: < 8 hours to 90% capacity
- Protection: protection for low battery-cut off and shut down
- Environment:
- Audible noise: < 40 DBA at 1 meter
- Ambient operating temperature: 0(Celsius) to +40(Celsius)
- Ambient storage temperature: -20(Celsius) to +40(Celsius)
- Operating altitude: up to 10,000ft.(3,000m)
- Relative humidity: 5 ~ 95% non-condensing
- EMI suppression: In accordance with FCC class A & B/EN 55022 class 2
- LED display:
- Line normal: green LED.
- Battery in use: slow flashing of orangr LED.
- Battery low: fast flashing of orange LED.
- Over load: red LED blackout after 5 sec. of flashing.
- Output short circuit: LED blackout
- Physical:
- Dimensions:390 x 125 x 190(1000A/1200A), 420 x 200 x 290(1200TA/1500TA/2000TAL)
- Net weight: 15kgws(1000A), 15.5kgws(1200A), 22kgws(1200TA), 24kgws(1500TA), 26kgws(2000TAL)
- General:
- User interface: on/off switch and cold start
- Audible alarms: on battery, low battery, overload
- Communication: DB-9 serial port with dry contacts(
Features
- UPS plus AVR(Automatic Voltage Regulator) allows 75% to 125% of input voltage range, which is the best Protection equipment for your LAN and PC.
- Gold Start: The UPS can be activated without utility power.
- Suitable for any available space due to small footprint design.
- Battery charging with current limit to extend battery's life.
- DB-9 connector: This remote interface can be used to connect with the Novel Netware, MS-DOS, MS-Windows V3.1, MS-Windows 95, MS-Windows NT, ARTISOFT LAN tastic, Microsoft LAN Manager and IBM LAN server.
- Optionally come with PHONE JACK(for fax machine).
- Output overload & short circuit protection.
- High/low voltage protection.
- Low battery auto shut down.
- Extended back up time with external battery. (Optional available upon request.)