Heavy duty design, extendible, outstanding performance, this UPS is specially designed for long periods of black out, generator environment, and countries with poor quality utility power.
Specifications
- Design: micro processor control, 60KHz design
- Input Voltage: 100V AC, 110V AC, 220V AC, 230V AC or 240V AC
- Input Voltage Range: +/- 15% (option 160-310VAC)
- Input Frequency: 50 Hz or 60 Hz +/- 5%
- Phase: single
- Capacity:
- CON-6.5K: 6500VA
- CON-8K: 8000VA
- CON-10K: 10000VA
- Power Factor: 0.8
- Output Voltage: 100V AC, 110V AC, 220V AC, 230V AC or 240V AC
- Output Voltage Regulation: +/- 2%
- Response Time On Load Variation: 2 MS (0-100% load change)
- Output Frequency: 50 Hz or 60 Hz
- Output Frequency Regulation: +/- 0.5%
- Harmonic Distortion: < 3% at 100% linear load
- Output Wave-form: pure sinewave
- Efficiency: > 85%
- Crest Ratio: 3 : 1
- Back Up Time/Full Load:
- CON-6.5K: 5 min.
- CON-8K: 15 min. (12V/17AH x 16), 25 min. (12V/26AH x 16)
- CON-10K: 10 min. (12V/17AH x 16), 18 min. (12V/26AH x 16)
- Back Up Time/Half Load:
- CON-6.5K: 12 min.
- Battery Type: sealed lead acid battery, maintenance free
- Battery Size: 12V/7AH or HR 1221W
- Number Of Batteries: 16
- Recharging Time: 8-10 hours to 90% charge after complete discharge
- Transfer Time While Line Failure: zero
- UPS To Bypass Or Vice Versa: less than 2MS
- Indicator:
- LCD: UPS status, I/P & O/P voltage, I/P & O/P frequency, battery voltage, and loading %
- Line: green LED
- Inverter: green LED
- Battery low: yellow LED
- By pass: yellow LED
- Fault: red LED
- Overload: yellow LED
- Alarm
- Battery Output: sounds every 4 seconds after AC input fails, (mute after 90 seconds for 4K / 5K / 6.5K / 8K / 10K)
- Battery Low: sounds every second when battery approaches low level
- UPS Fault: continuous alarm
- Overload Protection: 150% delay 30 seconds transfer to by pass & automatic re-transfer
- Short Circuit Protection: current limited and cut off, fuse, and breaker
- Over Temperature Protection: inverter auto cut off when heatsink temp. over 85 Celsius, then transfer to by pass
- Depth:
- CON-6.5K: 340mm
- CON-8K: 340mm
- CON-10K: 340mm
- Width:
- CON-6.5K: 480mm
- CON-8K: 480mm
- CON-10K: 480mm
- Height:
- CON-6.5K: 845mm
- CON-8K: 845mm
- CON-10K: 845mm
- Net Weight (battery include):
- CON-6.5K: 128KGS
- CON-8K: 100KGS
- CON-10K: 106KGS
- Shipping Weight (battery include):
- CON-6.5K: 163KGS
- CON-8K: 135KGS
- CON-10K: 141KGS
- Operating Temperature: 0 Celsius to 40 Celsius
- Relative Humidity: 10-90% non-condensing
- Noise Level: less than 55db at one meter from enclosure
- Long Back Up Time: all models can be extended for back up time from 1-48 hours except CON-3K
- Computer Linking: RS-232 interface to link with intelligent "power boss" software
Features
- Use the most advanced IGBT devices. Special pulse by pulse protection design ensures system durability.
- Special circuitry design to withstand high in-rush current, rugged construction for severe environment.
- Well-designed air-flow to avoid dust and dirt build up.
- Single board technology, reduces repair time to minutes.
- Combination mechanical structure, easy to assemble, suitable for SKD business.
- Compact size lighter weight and quiet operation, easy to transport.
- RS-232 port, communication capability.
Main Products
UPS (uninterruptible power supply)