It consists of two tranches of wax texture and temperature element contact action mechanism driving the composition, the use of paraffin when heated from a solid into a liquid volume suddenly increases to move fader control opening and closing of the contacts. With coolant temperature, the wax begins to expand, while the overwhelming tension spring frame by pushing the plunger rubber sealing film. When the cooling water temperature rose to 95 ℃, low contact is closed, the radiator fan motor power, low speed to 1600 r / min of.
When the cooling water temperature continues to rise to 105 ℃ when, due to continued expansion of the paraffin leaving the high-speed contact is closed, the radiator fan motor in high speed 2400r / min, in order to increase the cooling intensity. When the cooling water temperature drops, paraffin volume contraction, putting retraction leaving the contact is opened, the realization of the radiator fan motor control in the role of the contact tension.
When the cooling water temperature continues to rise to 105 ℃ when, due to continued expansion of the paraffin leaving the high-speed contact is closed, the radiator fan motor in high speed 2400r / min, in order to increase the cooling intensity. When the cooling water temperature drops, paraffin volume contraction, putting retraction leaving the contact is opened, the realization of the radiator fan motor control in the role of the contact tension.
Certificate
- ISO
Main Products
Thermostats, thermal protection, thermal switch, Temperature sensor