Measurement example: Measurement of an organic EL illumination panel during development
Since the commencement of high-definition TV broadcasting, there is an accelerating proliferation of high-quality display devices which support full HD for reproduction of sharp, high-resolution images. State-of-the-art technology is now achieving tone reproduction with contrasts of 100,000 : 1, offering an almost-real feeling. This has spurred technical competition for reproduction of "blacker blacks" in particular, resulting in the need for an instrument that can measure extremely low luminance.
In addition, the development of various light-emitting devices, including organic electroluminescent (EL) displays as well as conventional LCD and plasma displays, requires more accurate spectrum analysis. The CS-2000 is a polychromatortype spectroradiometer which achieves 100,000 : 1 contrast measurement with the worlds top level capability to detect extremely low luminance levels of 0.003 cd/m2.
Highly accurate measurement of luminances as low as 0.003 cd/m2
Konica Minoltas original optical design and signal-processing technologies provide accurate measurement of luminance/chromaticity down to extremely low luminances of 0.003 cd/m2.
Low-luminance measurements: From 0.003 cd/m2
Measurement accuracy: ±2% (Luminance)
Quick measurements even at low luminance
Designed to thoroughly eliminate mechanical and electrical noise factors, the CS-2000 makes quick measurements with good repeatability possible even at low luminance levels.
Measurement time for 1 cd/m2:
Approx. 5 sec. (FAST mode)
*
Konica Minoltas previous model CS-1000: Approx. 123 sec.
Low polarization error
The polarization error generated when using a reflection-type diffraction grating has been minimized to 2% (measuring angle: 1°). This ensures more stable measurements of display devices that use polarization, such as LCDs.
Half bandwidth of 5 nm
A half bandwidth of 5 nm, which is required for colorimetry (JIS Z 8724-1997, CIE122-1996), is ensured for the entire wavelength range, allowing accurate chromaticity measurement.
Selectable measuring angle for measurement of tiny areas
The CS-2000 enables you to select the optimum measuring angle according to the application.
Measuring angle selection: 1°, 0.2°, 0.1°
Minimum measuring area: o0.1 mm ( when the optional close-up lens is attached)
Practical design
The operating temperature range of 5 to 35°C ensures reliable operation at temperatures in actual work environments.
Measurement can be started after a warm-up time of only 30 seconds. (Measuring angle: 1°; Target luminance: 5 cd/m2 or more; 23°C)
Stable measurement even of periodic light sources
Internal synchronization measurement
Measurement at numerically-input frequency
External synchronization measurement
Measurement with line input of vertical synchronization signal to instrument
Multi-integration mode measurement
Measurement for reducing variations due to unsynchronized measurements or synchronized measurements of sources having irregular light-emission cycles
Easy operation with color LCD screen and simple operation panel
The color LCD screen and operation panel are located at the rear of the instrument. The simply arranged operation panel enables intuitive selection of necessary functions.
Since the commencement of high-definition TV broadcasting, there is an accelerating proliferation of high-quality display devices which support full HD for reproduction of sharp, high-resolution images. State-of-the-art technology is now achieving tone reproduction with contrasts of 100,000 : 1, offering an almost-real feeling. This has spurred technical competition for reproduction of "blacker blacks" in particular, resulting in the need for an instrument that can measure extremely low luminance.
In addition, the development of various light-emitting devices, including organic electroluminescent (EL) displays as well as conventional LCD and plasma displays, requires more accurate spectrum analysis. The CS-2000 is a polychromatortype spectroradiometer which achieves 100,000 : 1 contrast measurement with the worlds top level capability to detect extremely low luminance levels of 0.003 cd/m2.
Highly accurate measurement of luminances as low as 0.003 cd/m2
Konica Minoltas original optical design and signal-processing technologies provide accurate measurement of luminance/chromaticity down to extremely low luminances of 0.003 cd/m2.
Low-luminance measurements: From 0.003 cd/m2
Measurement accuracy: ±2% (Luminance)
Quick measurements even at low luminance
Designed to thoroughly eliminate mechanical and electrical noise factors, the CS-2000 makes quick measurements with good repeatability possible even at low luminance levels.
Measurement time for 1 cd/m2:
Approx. 5 sec. (FAST mode)
*
Konica Minoltas previous model CS-1000: Approx. 123 sec.
Low polarization error
The polarization error generated when using a reflection-type diffraction grating has been minimized to 2% (measuring angle: 1°). This ensures more stable measurements of display devices that use polarization, such as LCDs.
Half bandwidth of 5 nm
A half bandwidth of 5 nm, which is required for colorimetry (JIS Z 8724-1997, CIE122-1996), is ensured for the entire wavelength range, allowing accurate chromaticity measurement.
Selectable measuring angle for measurement of tiny areas
The CS-2000 enables you to select the optimum measuring angle according to the application.
Measuring angle selection: 1°, 0.2°, 0.1°
Minimum measuring area: o0.1 mm ( when the optional close-up lens is attached)
Practical design
The operating temperature range of 5 to 35°C ensures reliable operation at temperatures in actual work environments.
Measurement can be started after a warm-up time of only 30 seconds. (Measuring angle: 1°; Target luminance: 5 cd/m2 or more; 23°C)
Stable measurement even of periodic light sources
Internal synchronization measurement
Measurement at numerically-input frequency
External synchronization measurement
Measurement with line input of vertical synchronization signal to instrument
Multi-integration mode measurement
Measurement for reducing variations due to unsynchronized measurements or synchronized measurements of sources having irregular light-emission cycles
Easy operation with color LCD screen and simple operation panel
The color LCD screen and operation panel are located at the rear of the instrument. The simply arranged operation panel enables intuitive selection of necessary functions.