DIN5510-2 : Preventive fire protection in railway vehicles; Part 2: Fire behaviour and fire side effects of materials and parts, classification, requirement and test methods.
DIN 5510-2 fire test to Cable & Wire and small parts (handle, AD panel)
Product ID: DIN 5510-2
Send Inquiry
DIN 5510-2 fire test to Cable & Wire and small parts (handle, AD panel)
Firetc fire test center will provide Germany Standard DIN 5510-2 DIN 5510-2 fire test to Cable & Wire and small parts (handle, AD panel).
DIN 5510-2 Fire test to railway components-Standard
> DIN5510-2 : Preventive fire protection in railway vehicles; Part 2: Fire behaviour and fire side effects of materials and parts, classification, requirement and test methods.
DIN 5510-2 Fire test to railway components-Introduction
DIN 5510-2 determinate the fire classification of railway vehicle material and structure by burning behaviour, smoke density, dropping behavieour and toxic
DIN 5510-2 Fire test to railway component - Products Scope
DIN 5510-2 is acceptable to all train, railway vehicle, metro defined in EBO, ESBO, BOStrab
Fire test to railway components--small parts (handle, AD panel)
> Test Method: DIN 53438--Testing of combustible materials; response to ignition by a small flame
> Classification: S1
Fire test to railway components-structure(seal, flooring, wall)
> Test Method: DIN 54837 - Testing of materials, small components and component sections for rail vehicles - Determination of burning behaviour using a gas burner
> Classification: S2-S5, ST1-ST2, SR1-SR2
Fire test to railway components - flooring(including adhesive and glue
> Test Method: ISO 9239-1 Reaction to fire tests for floorings -- Part 1: Determination of the burning behaviour using a radiant heat source
> Classification: SF1-SF3
Fire test to railway components - Seat
> Test Method:DIN 5510-2, DIN EN 1021-1 and DIN EN 1021-2
Fire test to railway components – Electrical device
> Test Method:EN 60695
Fire test to railway components--Cable & Wire
> DIN EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions
> DIN EN 50266-2-4 Common Test Methods for Cables under Fire Conditions
>DIN EN 61034-2 Measurement of smoke density of cables burning under defined conditions
Smoke toxic test according new version DIN 5510-2:2009:05, DIN EN ISO 5659-2, Smoke toxic test (toxicity measured with FTIR):FED
Firetc fire test center will provide Germany Standard DIN 5510-2 DIN 5510-2 fire test to Cable & Wire and small parts (handle, AD panel).
DIN 5510-2 Fire test to railway components-Standard
> DIN5510-2 : Preventive fire protection in railway vehicles; Part 2: Fire behaviour and fire side effects of materials and parts, classification, requirement and test methods.
DIN 5510-2 Fire test to railway components-Introduction
DIN 5510-2 determinate the fire classification of railway vehicle material and structure by burning behaviour, smoke density, dropping behavieour and toxic
DIN 5510-2 Fire test to railway component - Products Scope
DIN 5510-2 is acceptable to all train, railway vehicle, metro defined in EBO, ESBO, BOStrab
Fire test to railway components--small parts (handle, AD panel)
> Test Method: DIN 53438--Testing of combustible materials; response to ignition by a small flame
> Classification: S1
Fire test to railway components-structure(seal, flooring, wall)
> Test Method: DIN 54837 - Testing of materials, small components and component sections for rail vehicles - Determination of burning behaviour using a gas burner
> Classification: S2-S5, ST1-ST2, SR1-SR2
Fire test to railway components - flooring(including adhesive and glue
> Test Method: ISO 9239-1 Reaction to fire tests for floorings -- Part 1: Determination of the burning behaviour using a radiant heat source
> Classification: SF1-SF3
Fire test to railway components - Seat
> Test Method:DIN 5510-2, DIN EN 1021-1 and DIN EN 1021-2
Fire test to railway components – Electrical device
> Test Method:EN 60695
Fire test to railway components--Cable & Wire
> DIN EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions
> DIN EN 50266-2-4 Common Test Methods for Cables under Fire Conditions
>DIN EN 61034-2 Measurement of smoke density of cables burning under defined conditions
Smoke toxic test according new version DIN 5510-2:2009:05, DIN EN ISO 5659-2, Smoke toxic test (toxicity measured with FTIR):FED