cooling tower:
Note: All the above cooling towers are energy saving type. Because the motor capacity is lower
than the cooling towers of the same kind, the water temperature for low noised and super
low noised cooling tower is 3~8°C, which is suitable for the cooling of air conditioner.
Super low noised cooling tower is based on more noise control on low noised cooling tower, whose standard noise value is 5dB(A) lower than corresponding noise value. It is suitable for the places which has high requirement for noise, such as hotel, hospital, public area and the places which are near the living area.
Water temperature for industrial type, that is mid & high temperature cooling towers is 10~25°C. Tower diameter, wind volume, wind pressure, capacity, height of packing are increase for this kind of towers. It is suitable for the cooling of industrial water.
Introduction for the code:
DBNL3-100 type:D-low noised ;B-FRP;N-Counter current;L-cooling tower;3-the 3rd change on type;100-nomical flow under standard working condition: 100m3/h;
GBNL3-100 type:G-industrial mid & high temperature reducing
CDBNL3-100 type:CD-super low noised
DBNL3J-100 type:J-water collecting(height of water pond for water collecting type is 300~400mm higher than normal type)
Note: All the above cooling towers are energy saving type. Because the motor capacity is lower
than the cooling towers of the same kind, the water temperature for low noised and super
low noised cooling tower is 3~8°C, which is suitable for the cooling of air conditioner.
Super low noised cooling tower is based on more noise control on low noised cooling tower, whose standard noise value is 5dB(A) lower than corresponding noise value. It is suitable for the places which has high requirement for noise, such as hotel, hospital, public area and the places which are near the living area.
Water temperature for industrial type, that is mid & high temperature cooling towers is 10~25°C. Tower diameter, wind volume, wind pressure, capacity, height of packing are increase for this kind of towers. It is suitable for the cooling of industrial water.
Introduction for the code:
DBNL3-100 type:D-low noised ;B-FRP;N-Counter current;L-cooling tower;3-the 3rd change on type;100-nomical flow under standard working condition: 100m3/h;
GBNL3-100 type:G-industrial mid & high temperature reducing
CDBNL3-100 type:CD-super low noised
DBNL3J-100 type:J-water collecting(height of water pond for water collecting type is 300~400mm higher than normal type)
Certificate
- BV
Main Products
FRP Cooling tower Medical equipment cable and wire