copper conductor pvc insulated sheath control cable
copper conductor pvc insulated sheath control cable
ZR-KVVP, ZR-KVV, ZR-KVVP2, ZR-KVVR1, rated voltage : 450/750V
2, working temperature: no more than 70°C.
3, model and name look following table
Conductor
Insulation
sheathed
screened
cable
Main application
ZR-KVVRP
Copper
pvc
pvc
Copper wire braiding
Flame retardant Flexible control cable
Fixed laying indoor with capability of moving and screening.
ZR-KVV
copper
Pvc
pvc
\
Flame retardant control cable
For laying indoor, trenches, ducts, and for fixed installation, the cable should be flame retardant.
ZR-KVVP2
copper
pvc
pvc
Steel tape shield
Flame retardant control cable
For laying indoor, trenches, ducts, and underground, the cable should be flame retardant and able to bear heavier external mechanical force, and for installation.
ZR-KVVR
copper
pvc
pvc
\
Flame retardant control cable
For laying indoor, and the cable should be flame-retardant flexible and movable.
4, conductor : copper conductor.
5, insulation material : PVC insulated.
6, PVC sheathed
7, pls provide the detailed cable or wire information as below,
(1), KVV, ZR-KVV model,450/750V copper conductor pvc insulated and sheathed control cable
MODEL
No. of Core
Nom. cross Section Area(mm2)
Insul. Thick (mm)
Sheath thick (mm)
No. of Core
Nom. cross Section Area(mm2)
Insul. Thick (mm)
Sheath thick (mm)
KVV, ZR-KVV
2
0.75~6
0.6~0.8
1.2
14
0.75~6
0.6~0.8
1.5~1.7
3
0.75~6
0.7~0.8
1.2~1.5
16
0.75~2.5
0.6~0.8
1.5~1.7
4
0.75~6
0.6~0.8
1.2~1.5
19
0.75~2.5
0.6~0.8
1.5~1.7
5
0.75~6
0.6~0.8
1.2~1.5
24
0.75~2.5
0.6~0.8
1.5~1.7
7
0.75~6
0.6~0.8
1.2~1.5
27
0.75~2.5
0.6~0.8
1.5~1.7
8
0.75~6
0.6~0.8
1.2~1.7
30
1.5~2.5
0.7~0.8
1.7
10
0.75~6
0.6~0.8
1.2~1.7
37
0.75~2.5
0.6~0.8
1.7
12
0.75~6
0.6~0.8
1.5~1.7
44
0.75~2.5
0.6~0.8
1.7~2.0
52
0.75~6
0.6~0.8
1.7~2.0
61
0.75~2.5
0.6~0.8
1.7~2.2
8, Application :
For laying indoors, in trenches, ground, and in ducts, for fixed installation, able to withstand heavier mechanical force, and for fixed installation.
9, executive Standard: GB9330-1988
10, Service Conditions
(1)The long-time working temperature of conductor of PVC insulated cable is 70oC
The long-time working temperature of conductor of XLPE insulated cable is 90oC
(1) The temperature for laying the cables can not be lower than 0oC.Permissible bending radius(r):unarmoured cable:r≥6D;(D: outer diameter of the cable);armoured or copper-tape screened cable:r≥12D;shielded flexible cable:r≥6D
ZR-KVVP, ZR-KVV, ZR-KVVP2, ZR-KVVR1, rated voltage : 450/750V
2, working temperature: no more than 70°C.
3, model and name look following table
Conductor
Insulation
sheathed
screened
cable
Main application
ZR-KVVRP
Copper
pvc
pvc
Copper wire braiding
Flame retardant Flexible control cable
Fixed laying indoor with capability of moving and screening.
ZR-KVV
copper
Pvc
pvc
\
Flame retardant control cable
For laying indoor, trenches, ducts, and for fixed installation, the cable should be flame retardant.
ZR-KVVP2
copper
pvc
pvc
Steel tape shield
Flame retardant control cable
For laying indoor, trenches, ducts, and underground, the cable should be flame retardant and able to bear heavier external mechanical force, and for installation.
ZR-KVVR
copper
pvc
pvc
\
Flame retardant control cable
For laying indoor, and the cable should be flame-retardant flexible and movable.
4, conductor : copper conductor.
5, insulation material : PVC insulated.
6, PVC sheathed
7, pls provide the detailed cable or wire information as below,
(1), KVV, ZR-KVV model,450/750V copper conductor pvc insulated and sheathed control cable
MODEL
No. of Core
Nom. cross Section Area(mm2)
Insul. Thick (mm)
Sheath thick (mm)
No. of Core
Nom. cross Section Area(mm2)
Insul. Thick (mm)
Sheath thick (mm)
KVV, ZR-KVV
2
0.75~6
0.6~0.8
1.2
14
0.75~6
0.6~0.8
1.5~1.7
3
0.75~6
0.7~0.8
1.2~1.5
16
0.75~2.5
0.6~0.8
1.5~1.7
4
0.75~6
0.6~0.8
1.2~1.5
19
0.75~2.5
0.6~0.8
1.5~1.7
5
0.75~6
0.6~0.8
1.2~1.5
24
0.75~2.5
0.6~0.8
1.5~1.7
7
0.75~6
0.6~0.8
1.2~1.5
27
0.75~2.5
0.6~0.8
1.5~1.7
8
0.75~6
0.6~0.8
1.2~1.7
30
1.5~2.5
0.7~0.8
1.7
10
0.75~6
0.6~0.8
1.2~1.7
37
0.75~2.5
0.6~0.8
1.7
12
0.75~6
0.6~0.8
1.5~1.7
44
0.75~2.5
0.6~0.8
1.7~2.0
52
0.75~6
0.6~0.8
1.7~2.0
61
0.75~2.5
0.6~0.8
1.7~2.2
8, Application :
For laying indoors, in trenches, ground, and in ducts, for fixed installation, able to withstand heavier mechanical force, and for fixed installation.
9, executive Standard: GB9330-1988
10, Service Conditions
(1)The long-time working temperature of conductor of PVC insulated cable is 70oC
The long-time working temperature of conductor of XLPE insulated cable is 90oC
(1) The temperature for laying the cables can not be lower than 0oC.Permissible bending radius(r):unarmoured cable:r≥6D;(D: outer diameter of the cable);armoured or copper-tape screened cable:r≥12D;shielded flexible cable:r≥6D
Certificate
- ISO 9001:2008
Main Products
cable, power cable, rubber cable, electric wire