Specification:
• Screen size: ¢400mm with 4 film clips
• Travel-X.Z axis: 250mm*150mm
• Y: 100mm
• Stage size: 450mm*200mm
• Stage load capacity: 30kg
• Net weight: 240kg
• Object lens:5x.10x.20x.50x.100x. (standard 10x), reflector attached
• Magnification accuracy: 0.08% contour, 0.12% surface
• Transmission illumination: 24v/150w halogen bulbs for contour
• Reflection illumination: 21v/150w halogen bulbs for surface(pairs of fiber optic lighting)
• Power supply: AC110-120v, 200-240v, single phase 50/60Hz
• Linear scale-X. Y axis: 0.05µm resolution
• Angle measuring: 0.01°or 1′resolution
• Accuracy:
Accuracy: ±(4+L/25)µm, L = length of the work piece measured ( unit: mm)
• Repeatability: 0.003mm
• Transmission: linear guide, fits fast moving
• Digital readout: DC3000 DRO with RS232 output
• Features:
(1) skew
(2) mm/inch conversion
(3) ABS/INC conversion
(4) Zero setting
(5) 1/2 calculation
(6) 0° 90° 270° 360° conversion
(7) Linear compensation
(8) RS232 output
(9) Geometric measurement
• Screen size: ¢400mm with 4 film clips
• Travel-X.Z axis: 250mm*150mm
• Y: 100mm
• Stage size: 450mm*200mm
• Stage load capacity: 30kg
• Net weight: 240kg
• Object lens:5x.10x.20x.50x.100x. (standard 10x), reflector attached
• Magnification accuracy: 0.08% contour, 0.12% surface
• Transmission illumination: 24v/150w halogen bulbs for contour
• Reflection illumination: 21v/150w halogen bulbs for surface(pairs of fiber optic lighting)
• Power supply: AC110-120v, 200-240v, single phase 50/60Hz
• Linear scale-X. Y axis: 0.05µm resolution
• Angle measuring: 0.01°or 1′resolution
• Accuracy:
Accuracy: ±(4+L/25)µm, L = length of the work piece measured ( unit: mm)
• Repeatability: 0.003mm
• Transmission: linear guide, fits fast moving
• Digital readout: DC3000 DRO with RS232 output
• Features:
(1) skew
(2) mm/inch conversion
(3) ABS/INC conversion
(4) Zero setting
(5) 1/2 calculation
(6) 0° 90° 270° 360° conversion
(7) Linear compensation
(8) RS232 output
(9) Geometric measurement
Main Products
profile projector, VMM, CMM, linear encoder, DRO, measuring software