UV-5800
UV-5800
METASH UV-5800 are developed for precise test, its stray light is only 0.05%T.They are flexible, easy to use and maximize value. The value is evident from the performance provided every day. The local stand-alone software provide functions of Basic Mode, Quantitative Test, Kinetics and System Utilities.
Features
1. Large LCD screen(128x64Dots).
Can display total 200 groups of data,5 groups per screen. Can display standard curve and kinetics curve.
2. System can also save the test results, total 200 groups of data and 100 standard curves can be saved in the RAM. Be Convenient for check and reload.
3. Data can be restored after a sudden power cut.
4. Auto setting wavelength.
5. Tungsten lamp & deuterium lamp can be turned on/off individually to extend lifetime.
6. The optional Metash application software M.Wave Professional provides complete control of the spectrophotometer from a Computer by the Built-in USB port. It can expand to the following functions: Quantitative, Kinetics, Wavelength Scan, Multi-wavelength & DNA/Protein Test.
7.Pre-aligned design makes it convenient to change lamps.
8.Large sample compartment, It can accommodate 5-100mm path length cuvettes with optional holders. A variety of optional accessories are under your choice.
1.Basic Mode
Absorbance,Transmittance or Concentration measurements.It can display and save 200 groups of data, 5 groups per screen.
2.Quantitative
i) Standard Curve
At most 9 standard samples can be used to establish a standard curve. The curve and its equation will be displayed on the screen simultaneously. You can measure your unknown concentration solutions by the curve.
Total 100 curves can be saved in the RAM.
ii) Coefficient Method
If you have known the coefficient k & b of the formula C=kA+b, you can input the value directly by the button, then to test your unknown solutions.
III) System Utilities
Lamp management, time & date set, get dark current, calibrate wavelength, default system, and some other system functions.
Model UV-5800
Wavelength Range 190-1100nm
Band Width 2nm
Wavelength Accuracy ±0.5nm
Wavelength Repeatability 0.2nm
Wavelength Setting Auto
Photometric Accuracy ±0.3%T
Photometric Repeatability 0.2%T
Photometric Display Range 0-200%T, -0.3-3.0A, 0-9999C
Stability 0.002A/h @ 500nm
Baseline Flatness ±0.0015A
Noise ±0.001A
Stray Light ≤0.05%T@220nm, 360nm
Data Output Port USB
Printer Port Parallel Port
Display LCD (128*64 Dots )
Lamps Deuterium Lamp
& Tungsten Halogen Lamp
Detector Silicon Photodiode
Dimension (L*W*H) 460*360*180mm
Weight 19kg
METASH UV-5800 are developed for precise test, its stray light is only 0.05%T.They are flexible, easy to use and maximize value. The value is evident from the performance provided every day. The local stand-alone software provide functions of Basic Mode, Quantitative Test, Kinetics and System Utilities.
Features
1. Large LCD screen(128x64Dots).
Can display total 200 groups of data,5 groups per screen. Can display standard curve and kinetics curve.
2. System can also save the test results, total 200 groups of data and 100 standard curves can be saved in the RAM. Be Convenient for check and reload.
3. Data can be restored after a sudden power cut.
4. Auto setting wavelength.
5. Tungsten lamp & deuterium lamp can be turned on/off individually to extend lifetime.
6. The optional Metash application software M.Wave Professional provides complete control of the spectrophotometer from a Computer by the Built-in USB port. It can expand to the following functions: Quantitative, Kinetics, Wavelength Scan, Multi-wavelength & DNA/Protein Test.
7.Pre-aligned design makes it convenient to change lamps.
8.Large sample compartment, It can accommodate 5-100mm path length cuvettes with optional holders. A variety of optional accessories are under your choice.
1.Basic Mode
Absorbance,Transmittance or Concentration measurements.It can display and save 200 groups of data, 5 groups per screen.
2.Quantitative
i) Standard Curve
At most 9 standard samples can be used to establish a standard curve. The curve and its equation will be displayed on the screen simultaneously. You can measure your unknown concentration solutions by the curve.
Total 100 curves can be saved in the RAM.
ii) Coefficient Method
If you have known the coefficient k & b of the formula C=kA+b, you can input the value directly by the button, then to test your unknown solutions.
III) System Utilities
Lamp management, time & date set, get dark current, calibrate wavelength, default system, and some other system functions.
Model UV-5800
Wavelength Range 190-1100nm
Band Width 2nm
Wavelength Accuracy ±0.5nm
Wavelength Repeatability 0.2nm
Wavelength Setting Auto
Photometric Accuracy ±0.3%T
Photometric Repeatability 0.2%T
Photometric Display Range 0-200%T, -0.3-3.0A, 0-9999C
Stability 0.002A/h @ 500nm
Baseline Flatness ±0.0015A
Noise ±0.001A
Stray Light ≤0.05%T@220nm, 360nm
Data Output Port USB
Printer Port Parallel Port
Display LCD (128*64 Dots )
Lamps Deuterium Lamp
& Tungsten Halogen Lamp
Detector Silicon Photodiode
Dimension (L*W*H) 460*360*180mm
Weight 19kg
Certificate
- CE
- ISO9001
- RosH
Main Products