Model Function Range Accuracy Controlled Output Object
RC-210M F01-F12 1 ºC Refrigeration, Defrost
RC-220M F01-F13 1 ºC Refrigeration, Defrost
RC-320M F01-F16 1 ºC Refrigeration, Defrost, Fan
RC-212M F00-F12 1 ºC Refrigeration, Defrost
RC-222M F00-F13 1 ºC Refrigeration, Defrost
RC-312M F00-F16 1 ºC Refrigeration, Defrost, Fan
RC-216M F01-F12 0.1 ºC Refrigeration, Defrost
RC-226M F01-F13 0.1 ºC Refrigeration, Defrost
RC-326M F01-F16 0.1 ºC Refrigeration, Defrost, Fan
Technical parameters:
Temperature controlling range: -40~110 ºC
Resolution: 0.1 ºC
Power supply: 220VAC±10% 50/60HZ
Consumption: ≤3W
Relay capacity: 5A or 10A
Operating temperature: -10~60 ºC
Operating humidity: 20%~85%
Code Function Setting range Default Unit Model
F00 Mode option 00:refrigeration 01:heating 00 / RC-xxxM series
F01 Start up temp. F02~110 -8 ºC
F02 Shut down temp. -40~F01 -10 ºC
F03 Compressor delay 0~20 3 Min.
F04 High temp. alarm 0~50 50 ºC
F05 Low temp. alarm 0~50 50 ºC
F06 Temp calibration -10~10 00 ºC
F07 Defrost cycle 0~99 6 Hr.
F08 Defrost time 0~99 30 Min
F09 Defrost duration 0~20 3 Min
F10 Defrost mode 00:electric-heating 01:thermal 00 /
F11 Defrost display 00:real–time temp.01:departed temp. 00 /
F12 Forcible refrigeration F02~110 30 ºC
F13 Defrost stop temp. -40~110 50 ºC
F14 Fan mode 00:start and stop with compressor simultaneously, close when defrost
01:operation continually, controlled by F13 00 /
F15 Fan stop temp. -40~110 10 ºC
F16 Communication signal 000~999 000 /
Suitable for aquarium equipment, air-conditioning, freezer, storage refrigeratory, display freezer, liquor cabinet and other refrigeration equipments. If you’re interested, pls contact me for more details.
RC-210M F01-F12 1 ºC Refrigeration, Defrost
RC-220M F01-F13 1 ºC Refrigeration, Defrost
RC-320M F01-F16 1 ºC Refrigeration, Defrost, Fan
RC-212M F00-F12 1 ºC Refrigeration, Defrost
RC-222M F00-F13 1 ºC Refrigeration, Defrost
RC-312M F00-F16 1 ºC Refrigeration, Defrost, Fan
RC-216M F01-F12 0.1 ºC Refrigeration, Defrost
RC-226M F01-F13 0.1 ºC Refrigeration, Defrost
RC-326M F01-F16 0.1 ºC Refrigeration, Defrost, Fan
Technical parameters:
Temperature controlling range: -40~110 ºC
Resolution: 0.1 ºC
Power supply: 220VAC±10% 50/60HZ
Consumption: ≤3W
Relay capacity: 5A or 10A
Operating temperature: -10~60 ºC
Operating humidity: 20%~85%
Code Function Setting range Default Unit Model
F00 Mode option 00:refrigeration 01:heating 00 / RC-xxxM series
F01 Start up temp. F02~110 -8 ºC
F02 Shut down temp. -40~F01 -10 ºC
F03 Compressor delay 0~20 3 Min.
F04 High temp. alarm 0~50 50 ºC
F05 Low temp. alarm 0~50 50 ºC
F06 Temp calibration -10~10 00 ºC
F07 Defrost cycle 0~99 6 Hr.
F08 Defrost time 0~99 30 Min
F09 Defrost duration 0~20 3 Min
F10 Defrost mode 00:electric-heating 01:thermal 00 /
F11 Defrost display 00:real–time temp.01:departed temp. 00 /
F12 Forcible refrigeration F02~110 30 ºC
F13 Defrost stop temp. -40~110 50 ºC
F14 Fan mode 00:start and stop with compressor simultaneously, close when defrost
01:operation continually, controlled by F13 00 /
F15 Fan stop temp. -40~110 10 ºC
F16 Communication signal 000~999 000 /
Suitable for aquarium equipment, air-conditioning, freezer, storage refrigeratory, display freezer, liquor cabinet and other refrigeration equipments. If you’re interested, pls contact me for more details.
Main Products
Temperature controller, digital thermometer, temperature panel