Liquid Turbine Flow Meter
Main features:
1. Widely measuring range, lower critical velocity less than 0.5m/s, less pressure loss, strong impact resistance of impeller.
2. With the high ability of anti-electromagnetic interference and shock resistance,
Adopting full-sealed self-lubricating bearings Isolation Protection, reliable performance & long working life.
3. The use of advanced ultra-low-power single-chip PC technology, the whole function of strong, low power consumption, superior performance.
4. Accuracy compensation with a non-linear function of intelligent traffic monitor.
Correction formula accuracy of better than ± 0.02%.
5. Meter parameters can be corrected on-line with LCD display.
6. Pressure compensation.
Main parameters:
Accuracy: 1% preferred, 1.5%
Nominal diameter: DN25-DN300
Working pressure: 1.6MPa, 2.5MPa, 4.0MPa
Medium temperature: -20° C~+80°C
Ambient temperature: -20° C~+55° C
Power supply:
1. LCD display without output type, 3.6V li battery. (>5 years working time. )
2. Pulse output type: A, without display pulse output, +5~24VDC
B, LCD display without pulse output, +12~24VDC
3. Two-wire 4-20mA output, +24VDC
Housing protection grade: IP65
Explosion-proof: ExiaIICT4 or ExdIIBT4
Remote: Pulse output signal remote distance ≤ 1000m
1. Widely measuring range, lower critical velocity less than 0.5m/s, less pressure loss, strong impact resistance of impeller.
2. With the high ability of anti-electromagnetic interference and shock resistance,
Adopting full-sealed self-lubricating bearings Isolation Protection, reliable performance & long working life.
3. The use of advanced ultra-low-power single-chip PC technology, the whole function of strong, low power consumption, superior performance.
4. Accuracy compensation with a non-linear function of intelligent traffic monitor.
Correction formula accuracy of better than ± 0.02%.
5. Meter parameters can be corrected on-line with LCD display.
6. Pressure compensation.
Main parameters:
Accuracy: 1% preferred, 1.5%
Nominal diameter: DN25-DN300
Working pressure: 1.6MPa, 2.5MPa, 4.0MPa
Medium temperature: -20° C~+80°C
Ambient temperature: -20° C~+55° C
Power supply:
1. LCD display without output type, 3.6V li battery. (>5 years working time. )
2. Pulse output type: A, without display pulse output, +5~24VDC
B, LCD display without pulse output, +12~24VDC
3. Two-wire 4-20mA output, +24VDC
Housing protection grade: IP65
Explosion-proof: ExiaIICT4 or ExdIIBT4
Remote: Pulse output signal remote distance ≤ 1000m
Main Products