The TELINK soft start controller - TL-ASSU220P3 provides an effective solution in reduction of compressor/induction motor start-up current, typically up to 70%, but still provides full startup torque for compressors and motors. Across the line starting of air-conditioner compressor or induction motors is accompanied by inrush currents up to 7-8 times higher than rated running current, and starting torque up to 3 times higher than running torque. The increased unnecessary torque results in sudden mechanical stress on the machine which leads to increased wear and higher service costs and reduced service life. Moreover, the high inrush current and current peaks may stress the power supply system to increased mains and generator loads which may lead to voltage dips results in brown-out or breaking down of other valuable equipment or system function.
Application
Air-conditioning (apply to single-phase 220V 1P/2P/3P)
Refrigerator (icebox)
Single-phase electromotor etc.
Main technical parameters
· Highest continuous working voltage: 266VAC.
· Highest continuous working current: 18A.
· Highest non-repetitive inrush current: 170A (
Application
Air-conditioning (apply to single-phase 220V 1P/2P/3P)
Refrigerator (icebox)
Single-phase electromotor etc.
Main technical parameters
· Highest continuous working voltage: 266VAC.
· Highest continuous working current: 18A.
· Highest non-repetitive inrush current: 170A (