LP1-D DC Contactor manufacturer
1. LP1-D DC Contactor Model: LP1-D09 DC Contactor, LP1-D12 DC Contactor, LP1-D18 DC Contactor, LP1-D25 DC Contactor, LP1-D32 DC Contactor, LP1-D4011 DC Contactor, LP1-D5011 DC Contactor, LP1-D6511 DC Contactor, LP1-D8011 DC Contactor, LP1-9511 DC Contactor
2. Brief Introductions of DC Operated AC Contactor:
DC Contactor produced in our company is used in circuit AC 50Hz/60Hz, rated voltage up to 660V, rated current up to 9-95A. It is widely applied for remote controlling circuit making, breaking and frequent starting AC motors.
3. Applications and Features of DC Operated AC Contactor:
1) Can be combined with the auxiliary contact group, air delayer, thermal relay devices etc.
2) Reliable performance and low consumption.
3) Insulating materials are used to protect and insulate the contacts.
4. Technical Data of DC Contactor:
Type Rated working current A
(AC-3) Conventional thermal current Ith(A) Rated working voltage Ue(V) Rated insulated voltage Uiv Controlled power (kw) Electric life (AC-3)
(104) Contacts number
220V 380V 660V
LP1-D09 9 20
380V
660V
660V 2.2 4 5.5 100 3P+NO or NC
LP1-D12 12 20 3 5.5 7.5 100
LP1-D18 18 32 4 7.5 9 100
LP1-D25 25 40 5.5 11 15 100
LP1-D32 32 50 7.5 15 18.5 80
LP1-D40 40 60 11 22 30 80 3P + NO and NC
LP1-D50 50 80 15 25 33 60
LP1-D65 65 80 18.5 37 37 60
LP1-D80 80 125 22 45 45 60
LP1-D95 95 125 25 45 45 60
1. LP1-D DC Contactor Model: LP1-D09 DC Contactor, LP1-D12 DC Contactor, LP1-D18 DC Contactor, LP1-D25 DC Contactor, LP1-D32 DC Contactor, LP1-D4011 DC Contactor, LP1-D5011 DC Contactor, LP1-D6511 DC Contactor, LP1-D8011 DC Contactor, LP1-9511 DC Contactor
2. Brief Introductions of DC Operated AC Contactor:
DC Contactor produced in our company is used in circuit AC 50Hz/60Hz, rated voltage up to 660V, rated current up to 9-95A. It is widely applied for remote controlling circuit making, breaking and frequent starting AC motors.
3. Applications and Features of DC Operated AC Contactor:
1) Can be combined with the auxiliary contact group, air delayer, thermal relay devices etc.
2) Reliable performance and low consumption.
3) Insulating materials are used to protect and insulate the contacts.
4. Technical Data of DC Contactor:
Type Rated working current A
(AC-3) Conventional thermal current Ith(A) Rated working voltage Ue(V) Rated insulated voltage Uiv Controlled power (kw) Electric life (AC-3)
(104) Contacts number
220V 380V 660V
LP1-D09 9 20
380V
660V
660V 2.2 4 5.5 100 3P+NO or NC
LP1-D12 12 20 3 5.5 7.5 100
LP1-D18 18 32 4 7.5 9 100
LP1-D25 25 40 5.5 11 15 100
LP1-D32 32 50 7.5 15 18.5 80
LP1-D40 40 60 11 22 30 80 3P + NO and NC
LP1-D50 50 80 15 25 33 60
LP1-D65 65 80 18.5 37 37 60
LP1-D80 80 125 22 45 45 60
LP1-D95 95 125 25 45 45 60