Name: Disposable Precision Infusion Set
Model No: IS-JM-3.0-A(B), IS-JM-5.0-A(B)
The infusion precision:5.0μm &. 3.0μm
Sterilization By E.O.(Oxygen Ethane),Non-Toxic,Non-Poison,Non-Pyrogenic
Advantage of the products:
Adopting advanced capillary filter membrane technology, multiple indexes exceed the national standard. National standard GB18458.1-2001 5.0μm in liquid medicine, infusible particle of 0μm is strained except that the rate should not be smaller than 90%, the velocity of flow demand is to be greater than or equal to 500ml/min. To 5.0μm following infusible particle has not made any regulation. The JM series filter which Shanghai Heroes Power Medical Appliance Co., Ltd. developed, in case of guaranteeing velocity of flow, can strain the aperture of getting rid of the particle to control in 3. 0μm, strain except that the rate is not smaller than 95%, the velocity of flow can reach and is greater than or equal 600ml/min.
The liquid medicine filters the structure for the vertical standing upright type, the side is filtered, filter effectually, have the advantage of being difficult to stop up.The area of filtration of JM series filter that this product adopts is about 5. 3cm2 (round filter) but tradition filter area only 1.2cm2,is much bigger than the traditional filter.It is difficult to take shape to stop up, has improved the result filtered.
With self-purging, this product can make gas and liquid separated. It is even more scientific than the method which the traditional transfusion system relying on to get rid of the air artificially. It has taken the course of its own on the domestic market, and has already obtained the appearance and practical patent. (Patent No.: Round type ZL 02 3 16551.0; ZL 02 2 65810.6 and Rectangular type ZL 02 3 12595.0; ZL 02 2 15930.4).
Model No: IS-JM-3.0-A(B), IS-JM-5.0-A(B)
The infusion precision:5.0μm &. 3.0μm
Sterilization By E.O.(Oxygen Ethane),Non-Toxic,Non-Poison,Non-Pyrogenic
Advantage of the products:
Adopting advanced capillary filter membrane technology, multiple indexes exceed the national standard. National standard GB18458.1-2001 5.0μm in liquid medicine, infusible particle of 0μm is strained except that the rate should not be smaller than 90%, the velocity of flow demand is to be greater than or equal to 500ml/min. To 5.0μm following infusible particle has not made any regulation. The JM series filter which Shanghai Heroes Power Medical Appliance Co., Ltd. developed, in case of guaranteeing velocity of flow, can strain the aperture of getting rid of the particle to control in 3. 0μm, strain except that the rate is not smaller than 95%, the velocity of flow can reach and is greater than or equal 600ml/min.
The liquid medicine filters the structure for the vertical standing upright type, the side is filtered, filter effectually, have the advantage of being difficult to stop up.The area of filtration of JM series filter that this product adopts is about 5. 3cm2 (round filter) but tradition filter area only 1.2cm2,is much bigger than the traditional filter.It is difficult to take shape to stop up, has improved the result filtered.
With self-purging, this product can make gas and liquid separated. It is even more scientific than the method which the traditional transfusion system relying on to get rid of the air artificially. It has taken the course of its own on the domestic market, and has already obtained the appearance and practical patent. (Patent No.: Round type ZL 02 3 16551.0; ZL 02 2 65810.6 and Rectangular type ZL 02 3 12595.0; ZL 02 2 15930.4).
Features
Main Products
infusion set ,precision infusion set ,precision filter,syringe