SOLID STATE HIGH FREQUENCY STEEL PIPE WELDER
Product ID: HF-W-100~HF-W-1000KW
Send Inquiry
A New Breakthrough in Technology. Highly-Efficient, Compact Transistor Inverter
Specifications
Output^$Output capacity (KW):
60, 100, 150, 200, 250, 300, 350, 400, 500, 600, 800, 1000
Frequency(KHZ):
80 ~ 400 KHZ^#Input ^$Voltage(V):
3O , 220/380/415/440 V 10% , 50/60 Hz
Capacity (KVA):
Output(kW)?.9=Input(kW) Output(kW)X 1.2=Input(kVA)^#Cooling Water^$Common specifications:
Water pressure 2.5 ~3.5kgf/cm2 Water temperature 25~40℃
Water flow(L/m):
50, 60, 100, 130, 200, 250, 300
Water inlet/outlet dia:
35A, 40A, 60A, 75A^#External Dirnensions^$Height H(mm):
1750
Inverter W1(mm):
800, 950, 1150, 1800, 2300, 3300, 4300
Cooling system W0(mm):
500, 600
Total Width W0(mm):
1300, 1450, 1650, 2350, 2800, 3900, 4900
Depth D(mm):
950, 1200, 1500
Mass(kg):
1600, 1700, 1900, 2000, 2800, 3000, 3300, 3800, 4800, 5500, 6300^#Others:^$1. Cooling Water System with dual ratings:Lower rating is for equipment with cooling water circulation while higher rating is for equipment without cooling water circulation system.
2. Feel free to contact us for information on inverters with other output capacities and frequencies not indicated in the above tables.
3. For product improvement, specifications and external appearance are subject to change without notice.^#
Features
Frequency and output^$The Generator accommodates a frequency range of 60kHz to 400 kHz at an output range of 60kw to 1000kw. In case of short time heating, output power can be increased.^#Energy savings & Compact design^$Because transistors are used instead of vacuum tubes, input power can be reduced by about 30% and cooling water can be saved by 50%
The comprehensive solid-state and low voltage design makes the unit compact in size to reduce the required installation space to one-fourth the space required by conventional vacuum-tube oscillator models. ^#Easy maintenance and inspection^$Transistors, printed circuit boards and other components are all placed at the front for easy maintenance access. Cooling water circulation system(option) helps to solve the water problems.^#Dependable protective circuits^$The protective circuits ensure safe inverter operation in case of touching coils, no-load operations, over-load operations and other operation errors. ^#Tripping operations^$Door interlock.Cooling water flow. Water inlet/outlet temp..IAC trip.IDC trip
Phase fault.LOW.F trip.HI.F trip.Tank fault(coil short).Tank cap. V trip ^#
Main Products
High Frequency Welding Machine,Preheater,Induction heatng,Steel Pipe