The rugged, compact LX Series was first developed with analog meters by the Xantrex engineering team in 1987. A digital version was introduced in 1990. This series meets of a broad range of lab applications requiring low voltage bench top power. It is most often used in schools, colleges, universities and service repair environments. This economic power supply feature isolated short circuit proof outputs protect power supply from short circuiting in the lab environment. The LX Series is available in dual and quad configurations to provide or variable outputs as needed.
Models (V-A) | LX 20-3 | LX 30-2 | LX 60-1 | LX 20-6 | LX 30-4 | LX 60-2 | LX 20-3 | LX 30-2 | LX 60-1 |
---|---|---|---|---|---|---|---|---|---|
Output Ratings: | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
Output Voltage | 0-20V | 0-30V | 0-60V | 0-20V | 0-30V | 0-60V | 0-20V | 0-30V | 0-60V |
Output Current | 0-3A | 0-2A | 0-1A | 0-6A | 0-4A | 0-2A | 0-3A | 0-2A | 0-1A |
Output Power | 60W | 60W | 60W | 120W | 120W | 120W | 60W | 60W | 60W |
Line Regulation: | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
Voltage (0.02% of V max. + 2mV) | 6mV | 8mV | 14mV | 6mV | 8mV | 14mV | 6mV | 8mV | 14mV |
Current (0.05%of I max. + 250mA) | 1.75mA | 1.25mA.0.75.mA | 3.25mA | 2.25mA | 1.25mA | 1.75mA | 1.25mA | 0.75mA | |
Load Regulation: | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
Voltage (0.02% of V max. + 2mV) | 6mV | 8mV | 14mV | 6mV | 8mV | 14mV | 6mV | 8mV | 14mV |
Current (0.05% of I max. + 250mA) | 1.75mA | 1.25mA | 0.75mA | 3.25mA | 2.25mA | 1.25mA | 1.75mA | 1.25mA | 0.75mA |
Meter Accuracy: | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
Voltage (1% of V max. + 1 count ) | 0.03V | 0.4V | 0.7V | 0.3V | 0.4V | 0.7V | 0.3V | 0.4V | 0.7V |
Current (1% of I max. + 1 count) | 0.04A | 0.03A | 0.02A | 0.07A | 0.05A | 0.03A | 0.04A | 0.03A | 0.02A |
Specifications
- Specifications are warranted over a temperature range of 0 - 30 Celsius. Above 30 Celsius, derate output linearly to zero at 70 Celsius.
- For input voltage variation from 104 to 127Vac, with constant rated load.
- For 0 - 100% load variation, with costant nominal line voltage.
- AC Input Voltage Range
- 104-127Vac, 47-63Hz.
- Maximum Input Current @ Low AC Line Limit
- 1.5A (60W dual), 4.0A (120W dual, 60W quad).
- Fixed Output Range
- +5V±4%, 0-3A minimum.
- Maximum Voltage Differential From Output To Safety Ground
- 500Vdc
- Tracking Accuracy (Quad Unit)
- Adjustable to within±(0.02%+5mV).
- Output Noise And Ripple (20Hz-20MHz)
- (Voltage) 0.5mVrms, 4mVp-p.
- (Current) 2mArms, 10mAp-p.
- Operating Ambient Temperature
- 0 - 30 Celsius with default local sensing.
- Above 30 Celsius, derate output linearly to zero at 70 Celsius.
- Storage Temperature Range
- -50 to +85 Celsius.
- Humidity Range
- 0-80% RH non-condensing.
- Voltage Mode Transient Response Time
- Maximum 100mus recovery to within 50mV of regulation point for 25% to 75% load change.
- Input Connector
- AC line cord with safety ground, 125V/15A rated.
- IEC320 connector.
- Output Connector
- Binding posts, 3/4" between centers.
- Size
- 60W dual unit-127mmH x 108mmW x 280mmD (5.2inH x 4.25inW x 11.0inD).
- 60W quad unit or 120W dual unit-127mmH x 216mmW x 280mmD (5.2inH x 8.5inW x 11.0inD).
- Weight (approx.)
- 60W dual unit-4.3kg (9.5 lb.).
- 60W quad unit or 120W dual unit-7.1kg (15.6 lb.).
- Agency Approvals
- CSA.
- Accessories
- AC Input: standard 115Vac M2-220Vac 47-63 Hz input
- M11: 10-turn current potentiometer
Features
- Extremely rugged
- Isolated short circuit proof output
- Switch selectable tracking on quad units
- 10 turn current potentiometer
Main Products
variable output power supplies from 0 - 600V & current range from 0 - 350A