The XFR Series is our newest line of power supplies. It incorporates our most advanced technology and design philosophy. This series was released in early 1996 to replace the XKW 1000 Watt and 3000 Watt models. The XFR Series uses zero voltage switch which results in increased efficiency and lower noise. This latest development in power conversion technology has only recently been implemented by manufacturers of fixed output power supplies. To ease production, the same input, main control, and digital interface boards are used in the 1200 Watt and 2800 Watt models. The difference between the two models is in the size of the magnetic and capacitors used. All differential parts on the main control board are mounted on a small "piggyback" board. This allows control boards to be built to the regular specifications of each model and the differential board to be added later. The XFR series caters to the application needs of computer controlled component burn-in, electroplating, process control, magnet control, and other high powered requirements currently being served by the XKW Series. The XFR is a 19" rack mountable power supply. The 1200 Watt model allows 1.75" (1U) vertical rack space. The 2800 Watt model is available in a 3.50" (2U) size.
Models (V-A) | XFR 7.5-140 | XFR 12-100 | XFR 20-30 | XFR 40-70 | XFR 60-20 | XFR 100-12 | XFR 150-8 | XFR 300-4 | XFR 600-2 |
---|---|---|---|---|---|---|---|---|---|
Output Ratings: | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
Output Voltage | 0-7.5V | 0-12V | 0-20V | 0-40V | 0-60V | 0-100V | 0-150V | 0-300V | 0-600V |
Output Current | 0-140A | 0-100A | 0-60A | 0-30A | 0-20A | 0-12A | 0-8A | 0-4A | 0-2A |
Output Power | 1050W | 1200W | 1200W | 1200W | 1200W | 1200W | 1200W | 1200W | 1200W |
Line Regulation | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
Voltage (0.05% of V max. + 2mV) | 5.75mV | 8mV | 12mV | 22mV | 32mV | 52mV | 77mV | 152mV | 302mV |
Current (0.05% of I max. + 2mA) | 72mA | 52mA | 32mA | 17mA | 12mA | 8mA | 6mA | 4mA | 3mA |
Load Regulation: | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
Voltage (0.075% of V max. + 5mV) | 11mV | 14mV | 20mV | 35mV | 50mV | 80mV | 118mV | 230mV | 455mV |
Current (0.075% of I max. + 5mA) | 110mA | 80mA | 50mA | 27.5mA | 20mA | 14mA | 11mA | 3mA | 6.5mA |
Meter Accuracy: | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
Voltage (1% of V max. + 1 count ) | 0.09V | 0.13V | 0.3V | 0.5V | 0.7V | 1.1V | 1.6V | 4V | 7V |
Current (1% of I max. + 1 count) | 1.5A | 1.1A | 0.7A | 0.4A | 0.3A | 0.13A | 0.09A | 0.05A | 0.03A |
Output Noise and Ripple (V): | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
rms | 10mV | 10mV | 10mV | 10mV | 10mV | 10mV | 20mV | 30mV | 40mV |
p-p (0-20MHz) | 75mV | 75mV | 75mV | 150mV | 150mV | 150mV | 150mV | 300mV | 400mV |
Stability: | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
Voltage (0.05% of V max.) | 3.75mV | 6mV | 10mV | 20mV | 30mV | 50mV | 75mV | 150mV | 300mV |
Current (0.05% of I max.) | 70mA | 50mA | 30mA | 15mA | 10mA | 6mA | 4mA | 2mA | 1mA |
Temperature Coefficient: | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
V (0.02% of V max./Celsius) | 1.5mV | 2.4mV | 4mV | 8mV | 12mV | 20mV | 30mV | 60mV | 120mV |
I (0.03% of I max./Celsius) | 42mA | 30mA | 18mA | 9mA | 6mA | 3.6mA | 2.4mA | 1.2mA | 0.6mA |
OVP Adjustment Range (5% to 10% of V max.) | 0.372-8.25V | 0.6-13.2V | 1-22V | 2-44V | 3-66V | 5-11V | 7.5-165V | 15-330V | 30-660V |
Specifications
- These specifications are warranted over a temperature range of 0 - 50 Celsius. From 50 to 70 Celsius, derate output current 2% per Celsius. Specifications are subject to chang without notice. Numbers posted are maximum values for model-dependent specifications.
- For input voltage variation over the AC input voltage range, with constant rated load.
- For 0 - 100% load variation, with constant nominal line voltage.
- Maximum drift over 8 hours with constant line, load, and temperature, after 30 minute warm-up.
- Change in output per Celsius change in ambient temperature, with constant line and load.
- AC Input Voltage Ranges
- 85-130Vac or 190-264Vac, 1 radius (17Amax. @ 120Vac; 8.8A max. @ 230Vac typical)
- Frequency: 47-63Hz
- Maximum Voltage Differential From Output To Safety Ground: 600Vdc
- Time Delay Form Power On Until Output Stable: 5 seconds maximum
- Voltage Mode Transient Response Time
- < 3ms for the output voltage to recover within 0.5% of its previous level after a step change in load current of 10% to 90% of rated output.
- Switching Frequency: nominal 78kHz (156kHz output ripple)
- Typical Efficiency: 85%
- Maximum Remote Sense Line Drop Compensation
- 5V/line (line drop is subtracted from total voltage available at supply output)
- Remote Monitoring
- Output Voltage And Current: 0-5V, 0-10V; 0 to full scale output, 1% accuracy
- Remote Start/Stop And Interlock
- TTL compatible input, selectable logic.
- Weight: 8.2kg (18 lbs.)
- Agency Approvals: CSA pending, CE pending
- Programming
- Remote analog programming (full scale input) - Voltage and current programming: 0-5k, 0-10k resistance: 0-5V (factory default), 0-10V voltage source. Optional isolated program and readback (V&I) -0-5v. Optional digital control RS232, GPIB, SAMI interface.
- Environmental specifications:
- Operating Temperature Range: 0-50 Celsius. From 50-70 Celsius, derate output current 2% per Celsius.
- Storage Temperature Range: -40 to +85 Celsius
- Humidity Range: 0-80% RH non-condensing
- Cooling: fan cooled. Air exhausts to rear. Over temperature shutdown: automatic restart or latch off.
- Programming Options
- ISOL-(isolated interface)
- RS232, GPIB
- SAMI-(single address multichannel interface)
Features
- Soft start operation limiting in-rush current on power up.
- Lower losses in power and higher efficiency.
- Quiet operation.
- Multiple fans to maintain cooling and speed controlled for long life.
- Analog programming as a standard feature.
- Multiple level shut down for safe operation
- Over voltage protection
- Internal digital interfaces.
- 10 turn potentiometer
- Multiple configurations remote sense
- Front panel switch for remote/ local mode
- TTL shutdown
- Switch selectable voltage
- Rack mountable
- Zero voltage switching
- Virtual power supply
- Front panel standby switch
- Thermal shutdown
- Current limit
- Strain relief cover
- Tracking