Optical Talk Set

Product ID: FTK-100

Send Inquiry
Item \ Model FTK-110 FTK-120 FTK-130
Communication system Full duplex Full duplex Half duplex
Wavelength 1310+/-20nm 1550+/-20nm 1300+/-30nm
FWHM 5nm or less than 5nm 5nm or less than 5nm 140nm or less than 140nm
Emitter type Laser diode Laser diode Laser diode
Transmission distance 80Km or more than 80Km 120Km or more than 120Km 15Km or more than 15Km
Dynamic range: 9/125Mu m 40Db 40Db N/A
Dynamic range: 62.5/125Mu m N/A N/A 20Db
Output power: 9/125M(TYP.) -405dBm or less than -4.5dBm -405dBm or less than -4.5dBm N/A
Output power: 62.5/125M(TYP.) -405dBm or less than -4.5dBm -405dBm or less than -4.5dBm -18dBm
Connector type ST, FC, SC, D4, SMA, Biconic ST, FC, SC, D4, SMA, Biconic ST, FC
Output stability(TPY)(1/8HRS) +/-0.05/+/-0.25Db +/-0.05/+/-0.25Db N/A
Temperature +/-0.02dBm/Celsius +/-0.02dBm/Celsius N/A
Modulation mode PCM PCM IM
LED indicators Tx, Rx, CW/2KHZ, Low battery, Power on Tx, Rx, CW/2KHZ, Low battery, Power on Tx, Rx
Specifications
  • Size:
    • Unit: 19.6(L) x 10.0(W) x 4.0(H)(Cm), 7.7(L) x 3.9(W) x 1.6(H)(In)
    • Shipping: 39.4(L) x 35.2(W) x 11.7(H)(Cm), 15.5(L) x 13.9(W) x 4.6(H)(In)
  • Weight: Unit is 0.58kg(1.28Lb) and shipping is 2.8kg(6.17Lb)
  • Powering:
    • 10 hours(typ.): Continuous use Ni-MH battery for operation(FTK-110, FTK-120 only)
    • 1 hours(typ.): Continuous use Alkaline battery for operation
    • 14 hours(typ.); Charging time for a full discharged battery
    • Continuous: Using AC Adapter
  • Temperature:
    • Operation: 0~50 Celsius(32~122 Fahrenheit)
    • Storage: -10~60 Celsius(14~140 Fahrenheit)
  • Humidity: 0 to 95%(Non-condensing)
  • Standard accessories: Carry case, AC charger, Ni-MH battery(FTK-110, FTK-120 only), Alkaline battery head set with boom microphone, Rubber bumper, Operation manual
Features
  • Measurements made at 23+/-2 Celsius unless otherwise specified
  • The test with Corning SMF-28 single mode fiber with FC connector
  • At 23+/-2 Celsius after a 20-minute warm-up period for 1 hour testing
  • At 23+/-2 Celsius after a 20-minute warm-up period for 8 hours testing
  • For temperature variation from 0~50 Celsius
  • Other connector types or specification can be provided on special request

Main Products